Request A Quote


HEAT TRACING, Heat Tracing, Heat Tracing Systems, remote glycol heat tracing
DESIGN SPECIFICATIONS

Model HT – 24 (Base model) Information

Construction Materials
Frame Aluminum
Fluid reservoir Leak tested @ 210 kpa
Gas capture chamber Leak tested @ 210 kpa
Exchanger guard Aluminum


Fittings
Hi-temp shutdown valve (factory set) 93 degrees Celsius
Fluid return throttle valve-with built in by-pass(factory set) 40 degrees Celsius
Pressure cap on fluid reservoir 48kpa
Gas capture chamber-Relief valve 35 kpa
Threaded fittings (painted) 2000 lb forged steel
Tubing and fittings Stainless steel
Heat exchanger Stainless steel ASME Rated


Pump – Non Lubricated
Maximum operating pressure 690 kpa
Operating temperature range -40 to 65 degrees Celsius
Flow rate (@60 SPM) 4.5 liters/minute


24” x 24” – Mark II Flush Mount Catalytic Heater
Heat input 16,000 Btu/hr.
Face temp. of heater @ maximum output 370 degrees Celsius
Gas consumption @ maximum output 16 SCF/Hr.


Dry Weight of Unit - Approx.70 Kgs.
Fluid capacity (500’ of 3/8” or 1/2" tubing) 10-12 liters
Fluid reservoir - Working volume 1.4 liters
Fluid reservoir expansion volume 1.2 liters


Circulation Fluid
Kold Snap-40 TM Heat Transfer Fluid No mixing required


Maintenance Schedule
Circulation Fluid Replace every 2 years
Pump Servicing Suggested every 2 years

Service and maintenance available from KoldKatcher. Contact us at: (403) 644-2268.

To download a .PDF copy of the MSDS, Click Here

NOTE: If you do not have a PDF viewer, click on the Adobe Reader icon to download your free copy in just a few minutes.


AVAILABLE OPTIONS

MODEL
HT 12
HT 24
HT 48
BTU/Hour
8000
16000
32000
Max. Ft. Heat Trace
250'
500'
1000'
Compact Design
 
Aluminum Frame
Powder Coated Cabinet
 
Insulated All Weather Enclosure
Building/Skid Mount
 
 
 
Remote Monitoring & Control

*Custom Models Available

Standard Items Include:
  • One year full parts warranty
  • Factory set high temp. shutdown
  • Thermal control valve
  • Spill containment
  • Exchanger guard
  • 25' Electrical starter cable
  • Catadyne exhaust vent shroud
Optional Items:
  • NEW- REMOTE MONITORING AND CONTROL FUNCTIONS
Desiccant Dryer    Particulate Filter    Flow Indicator   

Thermal Divert Valve    Regulators    Low Level Shutdown   


Heat Tracing | Technical Data | Heat Transfer Fluids | Contact Us | Home